Products

Overview
Features
Typical Applications
Specifications
Downloads
Related Products
Overview
The Variax VG Series is a coil feeder for presses that delivers high precision and speed.
It can be used for a variety of feeding conditions, such as for feeding irregularly shaped or soft material, in applications that call for micro-pitch feeding and ultra-high-speed feeding.
Features
Wide Product Lineup
Available in a wide range of models and sizes, and designed to meet various feeding conditions.
Ultra-high-speed Feeding
Capable of ultra-high-speed feeding rates of up to 3,600 spm (model VG15H).
Easy to Adjust
Easy dial adjustments of feed pitch, grip force, and material thickness (material thickness is adjustable only on the VG__(T) models).
Handles Various Materials
Inherently designed to feed irregularly shaped material, soft material, and processed material.
Typical Applications
  • Connector
  • IC lead frame presses
  • Beverage can presses
Specifications
VG Series General Specifications
Size Unit High-speed Type General-purpose Type Wide-stock Type
VG15H VG20H VG25(T) VG50(T) VG75(T) VG100(T) VG120W
Feed Pitch mm 0 to 15 0 to 20 0 to 25 0 to 50 0 to 75 0 to 100 0 to 120
Adjustment Units for Feed Pitch mm 0.02 0.02 0.02 0.02 0.02 0.02 0.001
Material Thickness *1, *2 mm 0 to 0.5 0 to 2 0 to 2 0 to 2 0 to 2 0 to 2 0 to 1
Grip Force N 400 to 1,200 400 to 1,200 400 to 1,200 400 to 1,200 400 to 1,200 300 to 3,000 600 to 2,400
Material Width mm 8 to 50 8 to 50 8 to 100 8 to 100 8 to 100 12 to 120 20 to 250
Max Strokes min-1 3,600 1,800 1,200 1,000 700 500 250
Max Feed Rate m/min 30 30 25 30 30 30 30
Feed Period deg 156 164 165 165 165 165 160
Repeatability *3 mm ±0.035 ±0.025 ±0.025 ±0.025 ±0.025 ±0.025 ±0.05
Pilot Release deg Approx. 72 Approx. 51 Approx. 49 Approx. 49 Approx. 49 Approx. 54 Approx. 49
Input Shaft Drive Ratio
(Input: Stroke)
1: 3 1: 2 1: 1 1: 1 1: 1 1: 1 1: 2
Operating Air Pressure *4 kPa 490 to 690 490 to 690 490 to 690 490 to 690 490 to 690 490 to 690 490 to 690
Lubrication System Forced lubrication Forced lubrication Oil bath/ forced lubrication Oil bath/ forced lubrication Oil bath/ forced lubrication Oil bath Forced lubrication
Power Supply V 100 VAC single phase, 50/60 Hz (115 VAC 50/60 Hz, 24 VDC)
Product Weight kg 60 60 60 60 60 150 290
*1 A material thickness adjustment dial is furnished on the high-speed type, some general-purpose types (VG___T), and the wide-stock type. For all other general-purpose types, material thickness is adjusted by shims.
*2 Contact Sankyo for material thicknesses of more than 1mm.
*3 The values listed here are Sankyo internal testing standards. Repeatability varies according to actual operating conditions.
*4 Compressed air with a high moisture content can lead to equipment failure. Furnish an air dryer or mist separator to prevent moisture (condensation).
Use an air filter with a porosity grade of 5 μm or less.
Make sure the air supply is at the specified pressure. Insufficient pressure may cause the release action to fail.
Downloads